E-Shop

CAN Inclination Sensor QG65N2-KDXYh-090H-CAN-CFM-UL

Ask For Price

DIS-SENSOR Netherlands Inclination sensor 90H

Model: QG65N2-KDXYh-090-CAN-CFM-UL

 

General Specifications

Housing Reinforced plastic injection molded (Faradex DS, black, EMI shielded by stainless steel fiber in PC)
Dimensions (indicative) 60x50x27 mm
Mounting Included: 4x M5x25 mm zinc plated steel pozidrive pan head screws, self-tapping (PZ DIN7500CZ) Mounting on flat surface only. Screw crosswise with maximum Torque 2.5 Nm
Ingress Protection (IEC 60529) IP67, IP69K (with IP69K mating connector)
Relative humidity 0 – 95% (non condensing, housing fully potted)
Weight approx. 110 gram
Supply voltage 10 – 32 V dc
Polarity protection Yes
Current consumption 50mA typ. For CFM models (daisy-chained CANbus): max. current internal T-junction: 2.5A
Operating temperature -40 .. +80 °C
Storage temperature -40 .. +85 °C
Measuring range ± 90°
Centering function Yes (CANout 0 = 0°), range: ±5°
Frequency response (-3dB) 0 – 10 Hz
Accuracy (overall @20°C) 0,15° typ.
Offset error ± 0,05° typ. (± 0,1° 2σ) after centering
Non linearity ± 0,1° typ., ± 0,15° 2σ, ± 0,2° max.
Sensitivity error not applicable. Repeatability 0,1°
Resolution 0,01°
Temperature coefficient T>0°C: 0.015°/K typ. en T<0°C: 0.03°/K typ.
Max mechanical shock 10,000g (max 0,2ms)
CAN interface (physical layer) According to ISO 11898-1 & ISO 11898-2 (CAN 2.0 A/B), Short circuit protected
CANopen application layer and communication profile CANopen, CiA301 V4.2.0 & EN 50325-4 + Device Profile CiA410 DSP 2.0.0 for inclinometers
Boot time < 0.5 s
Programming options by optional DIS Configurator and CANopen object dictionary (CAN parameters, filtering)

 

Transfer Characteristics

CANoutput = 100*α

 

Clipping outside measuring range

 

Zeroing can be done to eliminate mounting offsets.

 

 

Mechanical Dimensions (indicative only)

 

Categories: , Tags: ,
×