General Specifications |
|
Housing | Reinforced plastic injection molded (Faradex DS, black, EMI shielded by stainless steel fiber in PC) |
Dimensions (indicative) | 60x50x27 mm |
Mounting | Included: 4x M5x25 mm zinc plated steel pozidrive pan head screws, self-tapping (PZ DIN7500CZ) Mounting on flat surface only. Screw crosswise with maximum Torque 2.5 Nm |
Ingress Protection (IEC 60529) | IP67, IP69K (with IP69K mating connector) |
Relative humidity | 0 – 95% (non condensing, housing fully potted) |
Weight | approx. 110 gram |
Supply voltage | 10 – 32 V dc |
Polarity protection | Yes |
Current consumption | 50mA typ. For CFM models (daisy-chained CANbus): max. current internal T-junction: 2.5A |
Operating temperature | -40 .. +80 °C |
Storage temperature | -40 .. +85 °C |
Measuring range | ± 90° |
Centering function | Yes (CANout 0 = 0°), range: ±5° |
Frequency response (-3dB) | 0 – 10 Hz |
Accuracy (overall @20°C) | 0,15° typ. |
Offset error | ± 0,05° typ. (± 0,1° 2σ) after centering |
Non linearity | ± 0,1° typ., ± 0,15° 2σ, ± 0,2° max. |
Sensitivity error | not applicable. Repeatability 0,1° |
Resolution | 0,01° |
Temperature coefficient | T>0°C: 0.015°/K typ. en T<0°C: 0.03°/K typ. |
Max mechanical shock | 10,000g (max 0,2ms) |
CAN interface (physical layer) | According to ISO 11898-1 & ISO 11898-2 (CAN 2.0 A/B), Short circuit protected |
CANopen application layer and communication profile | CANopen, CiA301 V4.2.0 & EN 50325-4 + Device Profile CiA410 DSP 2.0.0 for inclinometers |
Boot time | < 0.5 s |
Programming options | by optional DIS Configurator and CANopen object dictionary (CAN parameters, filtering) |
Transfer Characteristics |
|
CANoutput = 100*α
Clipping outside measuring range
Zeroing can be done to eliminate mounting offsets.
|
Mechanical Dimensions (indicative only) |
|