High-Performance, Highly Efficient Venturi Air Movers
The unmatched performance of the COPPUS Jectair® HP is recognized throughout the industry. When compared with older-style air horns, the patented air mixing chamber of the Jectair® HP can produce up to a 40:1 air flow conversion and up to 26 percent savings on compressed air consumption.
Operating Principle: Compressed air or steam is admitted into the Jectair through a single inlet connection in the housing leading to the mixing chamber. The air or steam jetted from the nozzle creates a “Venturi” action that induces a large volume of surrounding air to enter the Jectair through the aerodynamic inlet bell. The air is then discharged at high velocity through the horn-shaped diffuser.
Note: Operating efficiency depends on compressed air volume and pressure (see charts)
PHYSICAL DIMENSIONS | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Jectair | A | B | C | D | E | No. | Width | Duct Size | Net Wt. | ||||||||
in | mm | in | mm | in | mm | in | mm | in | mm | in | mm | in | mm | lbs | kg | ||
3S-HP | 6.0 | 152 | 16.5 | 419 | 7.5 | 190 | 0.5 | 13 | 6.5 | 165 | 3 | 0.4 | 10 | 8 | 203 | 6 | 2.7 |
3-HP | 7.3 | 185 | 33.0 | 838 | 7.5 | 190 | 0.5 | 13 | 6.5 | 165 | 3 | 0.4 | 10 | 9 | 4.1 | ||
6-HP | 12.0 | 305 | 44.2 | 1,123 | 11.5 | 292 | 1 | 25 | 10.8 | 274 | 3 | 0.4 | 10 | 12 | 305 | 21 | 9.5 |
8-HP | 14.0 | 356 | 46.0 | 1,168 | 14.3 | 363 | 1 | 25 | 13.5 | 345 | 3 | 0.5 | 13 | 14 | 356 | 35 | 15.9 |
9-HP | 14.0 | 356 | 46.0 | 1,168 | 16.8 | 427 | 1 | 25 | 15.3 | 387 | 10 | 0.9 | 23 | 42 | 19 |
PERFORMANCE THROUGH VARIOUS LENGTHS OF DUCT (80 PSIG or 7 KG/CM2) | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Jectair | Free Air | 20 ft (6 m) | 30 ft (9 m) | 40 ft (12 m) | 50 ft (15 m) | |||||
cfm | m3/hr | cfm | m3/hr | cfm | m3/hr | cfm | m3/hr | cfm | m3/hr | |
3-HP | 1,700 | 2,888 | 1,550 | 2,634 | 1,480 | 2,515 | 1,410 | 2,396 | 1,350 | 2,294 |
6-HP | 4,500 | 7,645 | 4,020 | 6,830 | 3,860 | 6,558 | 3,715 | 6,312 | 3,580 | 6,083 |
8-HP | 6,250 | 10,620 | 5,550 | 9,431 | 5,280 | 8,972 | 5,050 | 8,581 | 4,850 | 8,241 |
9-HP | 8,000 | 13,592 | 6,850 | 11,640 | 6,550 | 11,130 | 6,250 | 10,620 | 6,000 | 10,195 |
EFFICIENCY AT SELECT INLET PRESSURES | ||||||||
---|---|---|---|---|---|---|---|---|
Inlet Pressure | Jectair | Air Flow | Air Consumption | Induction Ratio | Block Tight Static Pressure |
|||
cfm | m3/hr | cfm | m3/hr | in | mm | |||
60 psig or 4.2 kg/cm2 |
3S-HP | 1,370 | 2,328 | 47 | 80 | 29.1 | 5.8 | 147 |
3-HP | 1,520 | 2,595 | 47 | 80 | 32.3 | 5.8 | 147 | |
6-HP | 3,980 | 6,762 | 98 | 167 | 40.6 | 4.3 | 109 | |
8 | 5,600 | 9,515 | 178 | 302 | 31.5 | 3.9 | 99 | |
9 | 6,880 | 11,096 | 265 | 450 | 25.8 | 5.5 | 140 | |
80 psig or 5.6 kg/cm2 |
3S-HP | 1,530 | 2,600 | 61 | 104 | 25.1 | 7.5 | 191 |
3-HP | 1,700 | 2,888 | 61 | 104 | 27.8 | 7.5 | 191 | |
6-HP | 4,500 | 7,645 | 126 | 214 | 35.7 | 5.6 | 132 | |
8 | 6,250 | 10,620 | 233 | 396 | 26.8 | 5.2 | 132 | |
9 | 8,000 | 13,592 | 366 | 571 | 23.8 | 6.8 | 173 | |
100 psig or 7.0 kg/cm2 |
3S-HP | 1,660 | 2,820 | 72 | 122 | 23.0 | 8.9 | 224 |
3-HP | 1,860 | 3,160 | 72 | 122 | 25.8 | 8.9 | 224 | |
6-HP | 4,870 | 8,274 | 153 | 260 | 31.8 | 6.7 | 170 | |
8 | 6,750 | 11,469 | 282 | 479 | 23.9 | 6.2 | 157 | |
9 | 8,900 | 15,121 | 410 | 697 | 21.7 | 7.7 | 196 | |
* Maximum Operating Pressure 150 psig (10.5 kg/cm2) | ||||||||
* Induction Ratio = Air Flow/Air Consumption |
JECTAIR DECIBEL LEVEL | ||
---|---|---|
Model | Pressure | Decibel |
psig | dBa | |
Jectair 3 | 40 | 81 |
60 | 85 | |
80 | 88 | |
Jectair 6 | 40 | 85 |
60 | 89 | |
80 | 92 | |
Jectair 8 | 40 | 87 |
60 | 91 | |
80 | 94 | |
Jectair 9 | 40 | 88 |
60 | 92 | |
80 | 95 |
Brands | Coppus – USA |
---|---|
Select Model | 3-HP, 3S-HP, 6-HP, 8-HP, 9-HP |