General Characteristics:
Input Voltage: 100 – 600V
Output Voltage: 12 – 600V
Power: 10VA to 8000VA
Insulation Class: F/H
Ambient Temperature: 50°C Protection Degree: IP00
Terminals: Terminal Blocks |
Application:
Electrical isolation of the input and output side of a circuit
Step up/Step down purpose
|
Features:
Corrosion resistant varnish
Ability to handle extreme current peaks Long life
Able to with stand harsh site conditions
|
 |
General Characteristics:
Input Voltage: 100 – 600V
Output Voltage: 12 – 600V
Power: 50VA to 3000VA
Insulation Class: F/H
Ambient Temperature: 50°C Protection Degree: IP00
Terminals: Terminal Blocks |
Application:
Electrical isolation of the input and output side of a circuit
Step up/Step down purpose
|
Features:
Coil casted in epoxy resin for protection Suitable for hazardous areas Ability to handle extreme current peaks Long life
|
 |
General Characteristics:
Input Voltage: 100 – 600V
Output Voltage: 12 – 600V
Power: 30VA to 5000VA
Insulation Class: F/H
Ambient Temperature: 50°C Protection Degree: IP00
Terminals: Terminal Blocks |
Application:
Electrical isolation of the input and output side of a circuit
Step up/Step down purpose
|
Features:
Ability to handle extreme current peaks Coil enclosed in metal cover
No need for separate enclosure
Long life
|
 |
General Characteristics:
Mount transformers up to 3000VA
Made of Galvanized steel Powder coated to ASTM D3451
Withstand Temperature: 150°C Protection Degree: IP23/IP44/IP55/IP65
Termination: Knockouts/Glands |
Application:
Wall mounting enclosure for transformer.
|
 |
General Characteristics:
Input Voltage: 230 – 600V
Output Voltage: 230 – 600V
Power: 50VA to 1000VA
Insulation Class: F/H
Ambient Temperature: 50°C Protection Degree: IP00
Terminals: Terminal Blocks |
Application:
Electrical isolation
Step up/Step down purpose
Class protection
Voltage measurement
|
Features:
Ability to handle extreme current peaks Long life
Accuracy Class 1/2/3
|
 |
General Characteristics:
Input Voltage: 230 – 600V
Output Voltage: 230 – 600V
Power: 50VA to 300VA
Insulation Class: F/H
Ambient Temperature: 50°C Protection Degree: IP00
Terminals: Terminal Blocks |
Application:
Electrical isolation
Step up/Step down purpose
Class protection
Voltage measurement
|
Features:
Ability to handle extreme current peaks Windings enclosed in Epoxy resin Accuracy Class 1/2/3
|
 |
General Characteristics:
Input Voltage: 230 – 600V Output Voltage: 230 – 600V Power: 500VA to 80KVA Insulation Class: F/H
Ambient Temperature: 50°C Protection Degree: IP00 Terminals: Terminal Blocks |
Application:
Step up/Step down purpose
|
Features:
Configuration for multiple voltages Long life
|
 |
General Characteristics:
Input Voltage: 230 – 600V
Output Voltage: 230 – 600V Power: 3KVA to 500KVA Insulation Class: F/H
Ambient Temperature: 50°C Protection Degree: IP00 Terminals: Terminal Blocks |
Application:
Step up/Step down purpose
|
Features:
Configuration for multiple voltages
|
 |
General Characteristics:
Input Voltage: 230 – 600V
Output Voltage: 230 – 600V
Power: 5000VA to 1000KVA Insulation Class: F/H
Ambient Temperature: 50°C Protection Degree: IP00
Terminals: Stainless steel bolts |
Application:
Industrial applications
Electrical isolation & electrostatic shield between primary and secondary Step up/Step down purpose
|
Features:
Configuration for multiple taps at input & output
|
 |
General Characteristics:
Input Voltage: 230 – 600V
Output Voltage: 230 – 600V
Power: 5000VA to 100KVA
Insulation Class: F/H
Ambient Temperature: 50°C Protection Degree: IP00
Terminals: WAGO terminals |
Application:
Industrial applications
Electrical isolation & electrostatic shield between primary and secondary Step up/Step down purpose
|
Features:
Configuration for multiple taps at input & output
WAGO terminals for easier connection
|
 |
General Characteristics:
Suitable for transformers up to 500KVA Made of Galvanized steel
Powder coated to ASTM D3451 Withstand Temperature: 150°C Protection Degree: IP23/IP44/IP55/IP65 Termination: Gland plate – bottom entry |
Application:
Floor mounting enclosure for transformers
|
Features:
Able to withstand high temperatures Protection for transformer
Can be customized with wheels, wall brackets, sockets, temperature monitors etc
|
 |
General Characteristics:
Suitable for transformers up to 2500KVA Made of Galvanized steel
Powder coated to ASTM D3451 Withstand Temperature: 150°C Protection Degree: IP23/IP44/IP55 Termination: Gland plate – bottom entry |
Application:
Floor mounting enclosure for transformers
|
Features:
Separate partition for termination
Able to withstand high temperatures Protection for transformer
Can be customized with wheels, wall brackets, sockets, temperature monitors etc |
 |
General Characteristics:
A distribution transformer or service transformer is a transformer that provides the final voltage transformation in the electric power distribution system, stepping down the voltage used in the distribution lines to the level used by the customer.
Whether the transformers are used for infrastructure systems, industry or households, INTACT Controls provides the right transformer for every need – from compact distribution transformers to limited power transformers with ratings up to
5000 KVA (5MVA).
Transformers can be classified based on many factors like installation or losses which is the most important factor in the transformer. |
CONFIGURATIONS:
Standard Transformer – Hermetically sealed type
Input voltages 3.3Kv, 6.6Kv, 11Kv, 13.8Kv, 15Kv, 20Kv, 22Kv, 33Kv, 34.5Kv
Pole Mounted Transformer
Pad Mounted Transformer
Dead Front unit substation transformer
Package Substation
|
ACCESSORIES:
Oil Level Indicator
Thermometer
Pressure relief valve
Draining valve
Tap changer
DMCR relay (Optional)
Oil conservator (Optional)
Buchholz relay (Optional)
Air breather (Optional)
Rollers (Optional)
Winding temperature indicator (Optional)
|
 |
General Characteristics:
Our cast resin transformers suit typical distribution specifications and special designs to suit customers’ requirements either in IP00 specification, often required by LV switchboard manufacturers, or with sheet steel ventilated enclosures and cable boxes, which can be designed and built to suit bespoke specifications.
Cast resin transformers are constructed with their HV windings encapsulated in resin and are an excellent alternative to traditional oil-immersed transformers. Reduced sizes, self-extinguishing and high mechanical resistance to electro-dynamic stresses are just some of the qualities of |
CONFIGURATIONS:
Standard Transformer in IP00 & IP44 enclosure
Input voltages 400V, 600V, 3.3Kv, 6.6Kv, 11Kv,13.8Kv
Capacity 50KVA to 3MVA
Package Substation
|
ACCESSORIES:
Winding temperature indicator (Optional) Removable bi-directional rollers (Optional) PT-100 sensors
Cooling Fans
|
 |
General Characteristics:
Power tool transformers manufactured for the growing safety demands in the construction sector. These transformers are manufactured suitable for operation of tools, lighting, and site application.
These transformers are housed in reinforced cases providing security and durability for operation at site.
They are available in configurations of three phase and single phase depending on site conditions |
CONFIGURATIONS:
Capacity up to 80KVA
Input Voltages 380V, 400V, 415V & 440V for three phase
Input Voltages 220 or 230 for single phase
Output Voltages 12V/24V/ 110V/ 230V
Housed in GRP enclosure (1KVA to 5KVA)
Housed in IP55 Metal enclosure (5KVA to 80KVA)
|
Can be configured with multiple sockets/cable gland/male socket
input cable & plug
Socket configuration IP44/IP65
Enclosure configuration IP23/IP44/IP55
|