E-Shop

PROTRANS SINGLE PHASE / THREE PHASE TRANSFORMERS

Ask For Price

PROTRANS SINGLE PHASE / THREE PHASE TRANSFORMERS

 

General Characteristics:

Input Voltage: 100 – 600V

Output Voltage: 12 – 600V

Power: 10VA to 8000VA

Insulation Class: F/H

Ambient Temperature: 50°C Protection Degree: IP00

Terminals: Terminal Blocks

Application:

Electrical isolation of the input and output side of a circuit

Step up/Step down purpose

 

 

 

Features:

Corrosion resistant varnish

Ability to handle extreme current peaks Long life

Able to with stand harsh site conditions

 

 

General Characteristics:

Input Voltage: 100 – 600V

Output Voltage: 12 – 600V

Power: 50VA to 3000VA

Insulation Class: F/H

Ambient Temperature: 50°C Protection Degree: IP00

Terminals: Terminal Blocks

Application:

Electrical isolation of the input and output side of a circuit

Step up/Step down purpose

 

 

 

Features:

Coil casted in epoxy resin for protection Suitable for hazardous areas Ability to handle extreme current peaks Long life

 

 

General Characteristics:

Input Voltage: 100 – 600V

Output Voltage: 12 – 600V

Power: 30VA to 5000VA

Insulation Class: F/H

Ambient Temperature: 50°C Protection Degree: IP00

Terminals: Terminal Blocks

Application:

Electrical isolation of the input and output side of a circuit

Step up/Step down purpose

 

 

 

Features:

Ability to handle extreme current peaks Coil enclosed in metal cover

No need for separate enclosure

Long life

 

General Characteristics:

Mount transformers up to 3000VA

Made of Galvanized steel Powder coated to ASTM D3451

Withstand Temperature: 150°C Protection Degree: IP23/IP44/IP55/IP65

Termination: Knockouts/Glands

Application:

Wall mounting enclosure for transformer.

 

 

 

 

 

 

 

General Characteristics:

Input Voltage: 230 – 600V

Output Voltage: 230 – 600V

Power: 50VA to 1000VA

Insulation Class: F/H

Ambient Temperature: 50°C Protection Degree: IP00

Terminals: Terminal Blocks

Application:

Electrical isolation

Step up/Step down purpose

Class protection

Voltage measurement

 

 

 

Features:

Ability to handle extreme current peaks Long life

Accuracy Class 1/2/3

 

 

 

 

General Characteristics:

Input Voltage: 230 – 600V

Output Voltage: 230 – 600V

Power: 50VA to 300VA

Insulation Class: F/H

Ambient Temperature: 50°C Protection Degree: IP00

Terminals: Terminal Blocks

Application:

Electrical isolation

Step up/Step down purpose

Class protection

Voltage measurement

 

 

 

Features:

Ability to handle extreme current peaks Windings enclosed in Epoxy resin   Accuracy Class 1/2/3

 

 

 

General Characteristics:

Input Voltage: 230 – 600V Output Voltage: 230 – 600V Power: 500VA to 80KVA Insulation Class: F/H

Ambient Temperature: 50°C Protection Degree: IP00 Terminals: Terminal Blocks

Application: 

Step up/Step down purpose

 

 

 

 

 

 

Features:

Configuration for multiple voltages Long life

 

 

 

 

 

General Characteristics:

Input Voltage: 230 – 600V

Output Voltage: 230 – 600V Power: 3KVA to 500KVA  Insulation Class: F/H

Ambient Temperature: 50°C Protection Degree: IP00 Terminals: Terminal Blocks

Application: 

Step up/Step down purpose

 

 

 

 

 

 

Features:

Configuration for multiple voltages

 

 

 

 

 

General Characteristics:

Input Voltage: 230 – 600V

Output Voltage: 230 – 600V

Power: 5000VA to 1000KVA Insulation Class: F/H

Ambient Temperature: 50°C Protection Degree: IP00

Terminals: Stainless steel bolts

 

 

Application:

Industrial applications

Electrical isolation & electrostatic shield between primary and secondary Step up/Step down purpose

 

 

 

 

 

Features:

Configuration for multiple taps at input & output

 

 

 

 

 

 

General Characteristics:

Input Voltage: 230 – 600V

Output Voltage: 230 – 600V

Power: 5000VA to 100KVA

Insulation Class: F/H

Ambient Temperature: 50°C Protection Degree: IP00

Terminals: WAGO terminals

 

Application:

Industrial applications

Electrical isolation & electrostatic shield between primary and secondary Step up/Step down purpose

 

 

 

Features:

Configuration for multiple taps at input & output

WAGO terminals for easier connection

 

 

 

General Characteristics:

Suitable for transformers up to 500KVA  Made of Galvanized steel

Powder coated to ASTM D3451 Withstand Temperature: 150°C Protection Degree: IP23/IP44/IP55/IP65 Termination: Gland plate – bottom entry

Application:

Floor mounting enclosure for transformers

 

 

 

 

 

 

 

Features:

Able to withstand high temperatures Protection for transformer

Can be customized with wheels, wall brackets, sockets, temperature monitors etc

 

 

General Characteristics:

Suitable for transformers up to 2500KVA  Made of Galvanized steel

Powder coated to ASTM D3451 Withstand Temperature: 150°C Protection Degree: IP23/IP44/IP55 Termination: Gland plate – bottom entry

Application:

Floor mounting enclosure for transformers

 

 

 

 

 

 

 

Features: 

Separate partition for termination

Able to withstand high temperatures Protection for transformer

Can be customized with wheels, wall brackets, sockets, temperature monitors etc

General Characteristics:

A distribution transformer or service transformer is a transformer that provides the final voltage transformation in the electric power distribution system, stepping down the voltage used in the distribution lines to the level used by the customer.

Whether the transformers are used for infrastructure systems, industry or households, INTACT Controls provides the right transformer for every need – from compact distribution transformers to limited power transformers with ratings up to

5000 KVA (5MVA).

Transformers can be classified based on many factors like installation or losses which is the most important factor in the transformer.

CONFIGURATIONS:

Standard Transformer – Hermetically sealed type

Input voltages 3.3Kv, 6.6Kv, 11Kv, 13.8Kv, 15Kv, 20Kv, 22Kv, 33Kv, 34.5Kv

Pole Mounted Transformer

Pad Mounted Transformer

Dead Front unit substation transformer

Package Substation

 

 

 

 

 

 

 

 

 

 

 

 

 

ACCESSORIES:

Oil Level Indicator

Thermometer

Pressure relief valve

Draining valve

Tap changer

DMCR relay (Optional)

Oil conservator (Optional)

Buchholz relay (Optional)

Air breather (Optional)

Rollers (Optional)

Winding temperature indicator (Optional)

 

 

 

 

 

 

 

 

 

 

 

 

General Characteristics:

Our cast resin transformers suit typical distribution specifications and special designs to suit customers’ requirements either in IP00 specification, often required by LV switchboard manufacturers, or with sheet steel ventilated enclosures and cable boxes, which can be designed and built to suit bespoke specifications.

Cast resin transformers are constructed with their HV windings encapsulated in resin and are an excellent alternative to traditional oil-immersed transformers. Reduced sizes, self-extinguishing and high mechanical resistance to electro-dynamic stresses are just some of the qualities of

CONFIGURATIONS:

Standard Transformer in IP00 & IP44 enclosure

Input voltages 400V, 600V, 3.3Kv, 6.6Kv, 11Kv,13.8Kv

Capacity 50KVA to 3MVA

Package Substation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ACCESSORIES:

Winding temperature indicator (Optional) Removable bi-directional rollers (Optional) PT-100 sensors

Cooling Fans

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

General Characteristics:

Power tool transformers manufactured for the growing safety demands in the construction sector. These transformers are manufactured suitable for operation of tools, lighting, and site application.

These transformers are housed in reinforced cases providing security and durability for operation at site.

They are available in configurations of three phase and single phase depending on site conditions

 

CONFIGURATIONS:

Capacity up to 80KVA

Input Voltages 380V, 400V, 415V & 440V for three phase

Input Voltages 220 or 230 for single phase

Output Voltages 12V/24V/ 110V/ 230V

Housed in GRP enclosure (1KVA to 5KVA)

Housed in IP55 Metal enclosure (5KVA to 80KVA)

 

 

Can be configured with multiple sockets/cable gland/male socket

input cable & plug

Socket configuration IP44/IP65

Enclosure configuration IP23/IP44/IP55

 

 

 

 

 

 

×